by FARVIS
IMPACT BURNERS
MESH HEAD BURNERS
BAR BURNERS
SPECIAL EFFECTS & FILM BURNERS
BURNER SYSTEMS
CONTROL UNITS
GAS FITTINGS
FOR USE WITH PROPANE GAS AT 30 PSI / 2 BAR MAXIMUM PRESSURE
PLEASE SEE PREVIOUS PAGE FOR FURTHER IMPORTANT INFORMATION. ALL DIMENSIONS AND OUTPUTS ARE APPROXIMATE. PLEASE CONTACT US IF THESE FACTORS ARE CRITICAL. THESE ARE FOR 'INDUSTRIAL PROCESS USE'.
MUSHROOM BURNERS
ALSO KNOWN AS 'IMPACT BURNERS'
GENERAL PURPOSE 'UNBLOCKABLE' HEAVY DUTY BURNER

FLAME PATTERN
We pioneered the design and development of this type in the 1950's and it has yet to be bettered as a robust, high efficiency burner. It is ideal for bitumen and similar applications where spills can block the burner and is reliable and long lasting, made of heavy gauge steel and built to last.
STANDARD MUSHROOM HEAD BURNER

AN EXCELLENT GENERAL PURPOSE BURNER FOR BITUMEN BOILERS AND GENERAL APPLIANCES. 4 INCH DIAMETER HEAD
ALMOST UNBLOCKABLE. CREATES A DIFFUSED HEAT WHICH PRESERVES THE HEATING CONTAINER, REDUCES HOT SPOTS AND GIVES A FULLY CONTROLLABLE HEAT OUTPUT OVER THE ENTIRE RANGE. EXTREMELY HEAVY DUTY, EASY TO ADJUST AND STEEL CONSTRUCTION. CLEAN IT WITH A WIRE BRUSH AND BLOWTORCH! AVAILABLE IN VARIOUS STEM LENGTHS TO SPECIAL ORDER. THIS UNIT WAS SPECIFICALLY DEVELOPED FOR USE WITH FARVIS BOILERS AND OVER 50,000 UNITS HAVE BEEN MADE.
OUTPUTS CAN BE VARIED BETWEEN 20 AND 80 KW ENABLING THE UNIT TO BE USED FOR BITUMEN BOILERS BETWEEN 5 AND 60 GALLONS CAPACITY WITH ONLY MINOR INTERNAL ADJUSTMENTS.
LARGE MUSHROOM BURNER

PROVIDES MORE POWER FOR LARGE ASPHALT CAULDRONS AND BOILERS. 5 INCH DIAMETER HEAD. A VERY POWERFUL UNIT SUITABLE FOR TANK SIZES IN EXCESS OF 70 GALLONS. PLEASE CHECK BEFORE ORDERING AS THIS UNIT IS A SPECIALISED PIECE OF EQUIPMENT AND EXTREMELY POWERFUL ! SHOWN WITH OPTIONAL BASE PLATE. TUBE LENGTH TO SUIT YOUR REQUIREMENT.
NOTE: ALL MUSHROOM HEAD BURNERS CAN BE FITTED WITH A FLAT BASE PLATE TO MAKE THEM INTO FREE STANDING UNITS AS ILLUSTRATED.
HEAVY DUTY POT BURNERS
FLAME PATTERN
HEAVY DUTY GAUZE HEAD 'POT' BURNER
STANDARD SIZE ILLUSTRATED
A LOW COST AND ROBUST REPLACEMENT FOR OTHER BURNER TYPES WHERE RELIABILITY AND LONG LIFE ARE IMPORTANT. DESIGNED SPECIFICALLY FOR BITUMEN HEATING
THIS BURNER CAN BE CLEANED AND THE GAUZE HEAD UNBLOCKED WITH A WIRE BRUSH!
COMBINING THE BEST FEATURES OF RADIAL AND MESH HEAD BURNERS WITHOUT THE DRAWBACK OF WHISTLING AND BLOCKING UP. THE HIGH OUTPUT GAUZE FLAME HEAD FEATURES AN EASY TO CLEAN SURFACE THAT CAN NOT BE PERMANENTLY BLOCKED BY SPILLED BITUMEN. ALL YOU'LL NEED TO CLEAN IT IS A WIRE BRUSH!
HIGH OUTPUT GAUZE HEAD BURNER CAPABLE OF PROVIDING IN EXCESS OF 60 KW AT 2 BAR PRESSURE. THESE BURNERS ARE A HARDWEARING 'NO FRILLS' DESIGN WITH A HEAVY DUTY STAINLESS STEEL GAUZE HEAD. THE FLAME HEAD IS MADE FROM HEAVY GAUGE STEEL TUBE AND THE BODY FROM STEAM QUALITY PIPE. THE INJECTOR AND GAS UNIONS ARE STANDARD FARVIS COMPONENTS FOR EASE OF MAINTENANCE AND SERVICING.
THE FLAME SURFACE IS RECESSED TO PREVENT BLOCKAGES AND DAMAGE. THE BURNER IS FITTED WITH AN ANTI WHISTLE DEVICE . BURNERS ARE AVAILABLE FROM STOCK BUT CAN BE SUPPLIED WITH TUBE LENGTHS TO YOUR REQUIREMENTS.
DESIGN COPYRIGHT
FOR LONGER TANKS, CHEMICAL STRIPPING AND PREPARATION VATS, ASPHALT MIXERS AND HEATERS, INDUSTRIAL HOG ROASTERS, OVENS, KILNS AND POWDER COATING UNITS.
AVAILABLE IN VARIOUS LENGTHS AND MADE TO ORDER. CAN BE USED AS A SINGLE UNIT OR IN MULTIPLES.
(DESIGN COPYRIGHT)
HEAVY DUTY TUBE BURNER
LOW COST - VERY POWERFUL - EASY TO CLEAN
12" - 60" LENGTH

FLAME PATTERN

60" flame length ( note 12 inch ruler ! )
A 'NO FRILLS' HEAVY DUTY 1.25" DIAMETER BURNER DESIGNED TO WITHSTAND ABUSE ON SITE. EASY TO CLEAN FLAME PORTS THAT CAN BE WIRE BRUSHED CLEAN. AVAILABLE WITH CONTROL TAP AND FFD IF REQUIRED AND SUITABLE FOR THERMOSTAT CONTROL.
FLAME BAR LENGTH AVAILABLE UP TO 60 INCHES LONG.
.jpg)
The burner has superb mid and low range performance providing a steady and uniform heat for 'simmering' and progressive increase in heat when required. The photographs above show a 60" unit at low, medium and full power.
FARVIS burners are designed for site use and made from heavy duty steel. These units were designed for industrial process applications such as meat cooking and other operations where there is a need for easy cleaning and a robust, hard working burner.
Burners can be made to your required length and are economic to buy and to run. As standard we fit a heavy duty full length base plate but as they are made to order we can include mounting brackets and custom flame positions to suit your needs.

18" burner at full power
Larger units can supply 100 kW at full output pressure which is more than adequate for most uses! Progressive control from off to maximum is available instantly by altering the gas pressure at the regulator ( see details on regulator sets below ).
SPECIAL EFFECTS BURNERS

We can supply special effects units for film work and sets. The burner above was designed to simulate a burning car in a South African riot (!!) and we also specialise in equipment to produce a 'heat haze' effect for filming. With years of experience in the application of LPG equipment we are always interested in a new challenge.
MICRO BAR BURNERS
FOR SPECIALIST MINIATURE INDUSTRIAL APPLICATIONS USING LOW PRESSURE ( 37 MB ) LPG
12"micro burners ( special order only ). Specification and mountings to your requirements.
Burner flame pattern at full power.
HIGH OUTPUT SPECIAL PURPOSE 'RIBBON' BAR BURNER
This has a mesh ribbon giving a very even flame and a uniform height throughout the burner length. They are easier to block and not as robust as the previous type, but give a more uniform linear heating effect and are quieter at full power operation.
To special order only.


Examples of bar ribbon burners.
Standard lengths are 1.5 and 1 metre bar length with a flame length of slightly less. Other sizes to order as required.
BURNER KITS AND PACKAGES
for pre heaters, hot boxes and general industrial use

WE CAN SUPPLY A PACKAGE FOR EXPERIENCED FITTERS TO INSTALL, EITHER ON NEW EQUIPMENT OR AS A REPLACEMENT ON AN EXISTING HEATER. WE CAN PROVIDE VARIOUS BURNERS AND WHERE NECESSARY A COMPLETE KIT OF PARTS TOGETHER WITH A THERMOSTAT AND BURNER CONTROL SYSTEM.
This photograph shows a Propamiser and a large bar burner with a complete kit of parts for a heated tank.
FLAME FAIL SHUT OFF
THIS WILL SHUT OFF THE SUPPLY OF GAS IN THE EVENT OF THE FLAME GOING OUT, PREVENTING AN UNCONTROLLED ESCAPE OF GAS. IT HAS MANY ADVANTAGES BUT IT IS A RELATIVELY SENSITIVE SYSTEM AND CAN BE SUBJECT TO DAMAGE IF USED IN WET OR AGGRESSIVE CONDITIONS. HENCE IT IS NOT FITTED AS STANDARD TO INDUSTRIAL EQUIPMENT.
THIS PHOTO IS A CLOSE UP OF A FLAME FAILURE SHUT OFF AND AUXILIARY CONTROL TAP FITTED TO A BAR BURNER. THIS MODIFICATION CAN BE FITTED TO ANY OF OUR BURNERS ALTHOUGH A PILOT LIGHT MAY BE NEEDED IN SOME CASES.
THIS MODIFICATION MUST BE SPECIFIED AT THE TIME OF ORDER.
Available on standard mushroom burner, heavy duty pot burner and bar burners.
HOSE & REGULATOR SET
THE SAFE WAY TO OPERATE YOUR EQUIPMENT - BITUMEN BOILERS MUST USE ARMOURED HOSE.

4 METRE HEAVY DUTY ARMOURED GAS HOSE TO BRITISH STANDARD AND HIGH FLOW ADJUSTABLE REGULATOR, PRE ASSEMBLED AND READY TO OPERATE. HOSE END FITTINGS SCREW DIRECTLY TO OUR EQUIPMENT WITHOUT THE NEED FOR HOSE ADAPTERS OR PIPE CLIPS. MADE TO OUR SPECIFICATION BY A MAJOR SUPPLIER OF QUALITY BRITISH GAS EQUIPMENT THIS UNIT IS LONG LASTING, ROBUST AND RELIABLE.
HOSE LENGTHS

SEPARATE LENGTHS OF ARMOURED GAS HOSE AND FITTINGS ARE AVAILABLE WITH PRE MADE 1/4" MALE AND NUT/CONE FITTINGS TO FIT TO A STANDARD 1/4" REGULATOR FEMALE OUTPUT AND FARVIS BUILT EQUIPMENT. STANDARD LENGTH IS 12 FEET (4m ) or 15 FEET ( 5 m ).
FITTINGS: 1/4" BSPT MALE AT REGULATOR END - 1/4" CONE & 1/4" CAPTIVE NUT AT APPLIANCE END
NOT ILLUSTRATED: BARE LENGTHS OF SINGLE MESH STEEL BRAIDED ARMOURED HOSE AVAILABLE "FROM THE REEL" IN LENGTHS UP TO 120 FEET TO SUIT CUSTOMER REQUIREMENTS. FITTINGS AND HOSE CONNECTORS FROM STOCK.
Note: it is extremely dangerous to operate gas equipment in a position where you can't reach the gas cylinder or with an excessive length of hose.
DO NOT OPERATE WITH THE APPLIANCE ON A ROOF AND THE CYLINDER AT GROUND LEVEL
MULTI-CYLINDER CONNECTIONS
IF YOU NEED A LARGE OFF-TAKE OF GAS
OR YOUR CYLINDERS BEGIN TO 'FREEZE BACK' AND GAS OUTPUT DROPS ALTHOUGH THERE IS STILL PLENTY OF GAS IN THE CYLINDER, USUALLY WITH 'SNOW' FORMING ON THE OUTSIDE OF THE CYLINDER, THIS WILL USUALLY PROVIDE THE ANSWER -
CONNECT
TWO OR MORE CYLINDERS TO ONE APPLIANCE
OR

TWO APPLIANCES TO ONE GAS CYLINDER!
ADVICE AND ORDERS: 01275 46 4446